Digital
Bioamp System for EEG, ABR, EMG and Evoked Potentials |
|
|

|
 |
 |
 |
 |
DBA-S
Surface System
- 2 or
4 channel operation, true independent differential
operation.
- Gain
settings from 100x to 1,000,000x.
- Easy
to use front panel controls.
- Programmable
second order high pass and low pass, and 50/60Hz
notch filtering.
- Isolating
noise immune optical interface to head stages.
- Automatic
overload and clip monitoring.
- Single
button impedance checking (1 kHz adjustable).
- Built
in programmable test signal output.
- Long
35 hour battery life with auto power-down battery
saver.
- Programmable
filters from 5Hz to 5khz (high) 7khz (low).
The DBA-S Digital Biological Amplifier System is a high
performance programmable amplifier for EEG, EMG and ABR
recording. Employing the latest in Digital Signal
Processing (DSP) technology and specialized analogue and
digital circuits, the DBA-S is the first digital
biological amplifier. The four-channel headstage amplifies
and digitizes biological signals using high performance
instrumentation amplifiers and special high resolution A/D
converters. The headstage is connected to the controller
/receiver via a noise immune optical fibre, offering
optically isolated loss-less communication. Digital Signal
Processors provide precision programmable high pass, low pass
and 50/60 Hz notch filtering and automatic
impedance measuring. Processed headstage signals are
converted back to analogue in the DB4 and made available on
front panel BNC connectors. The DBA-S can be ordered with
two or four channels and later upgraded to allowing up to
512 channels.
. 
The optional Computer Control
Interface (DBA-C) allows you to control the amplifier
settings from a PC. Software control can be either through
the software interface that is provided or by programming
from your own software (included are drivers for MATLAB,
Delphi, Microsoft Visual C++, and Visual Basic).
|
 |
| |
|
|
| |
| SPECIFICATIONS |
| Differential Input
Impedance |
1010
ohms
|
| Input
Bias Current |
5
nA |
| Noise |
10
nV/Hz 1/2 at 1 kHz |
| Common-Mode
Rejection |
>90
db |
| Headstage
Power |
4
AA batteries, 35 hrs |
| Amplification
Settings |
Off, 100,
200, ...900,
1, 2,
3,... 9K
10, 20,
30,... 90K
100, 200,
300,... 1000K
|
| System
Group Delay |
- 2 Channel
-- 1.0 ms
- 4 Channel
-- 2.0 ms
|
| Filter
Rolloff |
12
dB/octave, Butterworth |
| Filter
Settings |
|
- HIGH PASS
|
- Off (2 Hz)
- 5 Hz to
5kHz
|
- LOW PASS
|
5
Hz to 7 kHz (4 channel)
5 Hz to 15 kHz (2 channel) |
| Notch
Filtering |
50,
60, 100, 120 150, 180 Hz |
| Output
Range |
±10
V |
| InPut
Range |
±10
mV |
| Conversion
Rate |
2 Channel
-- 24 kHz
4 Channel
-- 12 kHz
|
|
MODELS |
| DBA-S-2 |
2-Channel Bio-Amp System for Surface Electrodes |
 |
| DBA-S-4 |
4-Channel Bio-Amp System for Surface Electrodes |
 |
| DBA-H-1 |
1-Channel Bio-Amp System for High Impedance
Electrodes |
 |
| DBA-H-4 |
4-Channel Bio-Amp System for High Impedance
Electrodes |
 |
| DBA-S-HR |
4-Channel Bio-Amp System Expansion Kit for Surface
Electrodes |
 |
| DBA-H-HR |
4-Channel Bio-Amp System Expansion Kit for High
Impedance Electrodes |
 |
| DBA-FOC |
Replacement Fibre Optic Cable |
 |
| DBA-RP-1 |
Replacement Active Cable for DBA-H-1 (1 m with 1
mm pins) |
 |
| DBA-RP-4 |
Replacement Active Cable for DBA-H-4 (1 m with 1
mm pins) |
 |
| DBF-1 |
Single Channel Digital Programmable Filter |
 |
| DBS-1 |
Audio Monitor for DB4 |
 |
| 500310 |
1.5 mm to 2 mm plug adaptor (DBA-S only) |
 |
| 500323 |
replacement 1 mm 3 pin connector for DBA-H - 1
amplifier |
 |
| 500324 |
replacement 1 mm 6 pin connector for DBA-H - 4
amplifier |
 |
| 500102 |
0.031 inch to 2mm Socket Metal Electrode Holder |
 |
| 500330 |
Snap electrode cable (40 inches), 1.5 mm safelead
(7 wires) |
 |
| EL203 |
Disposable Ag/AgCl Snap Electrode (30) pack |
 |
Systems include HS4, DB4, cables, XB1
rack mount, power supply. Expansion Kits contain
HS4, DB4, cables.
* Computer interface includes XBUS optical
interface, ISA PC card, cables,
software. |
|
|
 |
|
Betterskin
Electrodes
| Cables and Connectors