Products Services Careers About WPI     Contact Us Quote
 Microprobe Thermometers
  Microprobe Thermometer is the instrument of choice for biological and laboratory temperature measurements.  

  • Super Accuracy 
  • Fast Response 
  • Analogue output signal 
  • Temp probes for all uses 
  • Multiple inputs

These thermometers are very versatile, providing fast response, high accuracy and stability with digital display and analogue signal for connection to a computer or recorder. With the wide selection of probes, the instruments can be used in almost any application.

BAT-10 This is the most versatile thermometer available. The instrument has a wide temperature range and fast response with most microprobes. The BAT-10 accuracy is NIST traceable and in each of the two temperature ranges, the accuracy is the same as the resolution. There are three microprobe inputs, 1 and 2 can be selected as separate inputs while 2 and 3 will read the differential temperature measurement between the two. The instrument has automatic warnings for low battery or faulty probes on the digital display. The linearized analogue output (LOP) signal allows ease of connection to a data acquisition system or recorder.

BAT-12 This thermometer has a sealed construction making it water, dust and fume resistant. The BAT-12 has a single microprobe input and a single range with the same high accuracy as the BAT-10. Comes complete with carrying case.

The thermometers can be used with any “Type T” thermocouple. Select a temperature microprobe on the following page for your specific application.

Microprobes

     
 

 

SPECIFICATIONS
  BAT 10 BAT 12
Temperature Range & Resolution -200°C to +400ºC, 1ºC resolution -100°C to +199.9ºC, 0.1ºC resolution
. -100°C to +199.9ºC, 0.1ºC resolution .
Differential Temp. Range -19.99°C to +19.99ºC N/A
. Linearization centred at 40°C .
. 0.01°C resolution .
Accuracy . .
1° Range
1°C ±1 least significant digit 0.1°C ± 1 digit between 0-50°C
0.1° Range
0.1°C ± 1 least significant digit 0.1% ± 1 digit over full range
Diff. Range
0.01°C ± 1 least significant digit  
Repeatability
± 1 least significant digit  
Calibration Conformity Conforms to NIST tables Follows NIST thermocouple tables within 1 digit
Display 3.5 Digit LCD 3.5 Digit LCD
Input Socket Miniature, quick disconnect, copper-constantan Miniature, quick disconnect, copper-constantan
Analogue output Non-linearized set at 1.6 V, corresponding to temperature of 401°C ª 10 mV per degree C
Power Supply/Batteries
BAT-10: 4 alkaline “C” cells (life: 1000 hr)
BAT-10R: 4 Ni-Cad “C” cells (rechargeable unit)
BAT-12: 9V cell
BAT-12R: 9V Ni-Cad with charger
Sensors
One WPI Type T thermocouple input
Ambient Operating Range: 15-45°C
Three WPI Type T thermocouple inputs
.
.
Ambient Temperature Compensation:
Auto-compensated to 0.1°C from 0°C to 50°C
Dimensions 21.6 x 22.9 x 8.9 cm (8.5 x 9 x 3.5 in.) 12.7 x 6.4 x 15.2 cm (5 x 2.5 x 6 in.)
Weight 1.6 kg (3.5 lb), including carrying case 1 kg (2 lb), including carrying case
 