The IITC Tail Flick Analgesia Meter measures latency
and/or temperature threshold when detecting properties
of narcotic and strong non-narcotic drugs on mice and
rats. A built-in Timer is automatically stopped when the
animals’ tail flicks out of the beam of light, test
result will be displayed on readout for viewing. An
overhead halogen light source is in a constant “ON”
(idle state). A pre focused heat source supplies an area
of 4X6mm stimulation to the tail. A built-in sensor in
the tail groove detects the tail flick of the animal.
The tail groove is a non-metallic material to avoid
unnecessary conditioning of your animals; unlike other
systems. If the animal does not flick their tail within
the pre programmed cut-off time; the heat source shuts
off automatically; avoiding tissue damage. Built-in
timer displays the reaction time in 0.01 second
increments. Control of system can be from either the
front panel or supplied footswitch: Start, Stop and
Reset of tests.
TAIL TEMPERATURE OPTION (T)

Measurement of tail temperature at all times.
Trigger temperature is automatic at start of every
test. Warms tail to preset temperature (set by user) and
then tests start, allowing all tail temperatures to be
identical.
This optional feature allows automatic preheating of
the tail up to 75 degrees c., ensuring all experiment
protocols to be precisely controlled and repeated. Once
a preset temperature is reached, the test and timer
start automatically. Once the animal reacts via tail
flick the timer and heat source stop and test results
are displayed. Readout will now show in repeatable
sequence, start , end temperatures and test time. This
unique feature stores the set temperature unless
otherwise changed; eliminating temperature variations
from test to test. We recommend that animals be
restrained with one of the IITC restrainers.
This unit solves the problem associated with “tail
temperature prior to and at the end of testing.” See
article: KJELL HOLE AND ARNE TJOLSEN: The Tail-Flick
Formalin Test in Rodents: Changes in Skin Temperature as
a Confounding Factor. Pain 53 (1993) pages. 247-254
Elsevier.
Two year warranty
120/240V
CE
Features
- Tail Temperature Optional (T)
- Precise programmable digital control
- Humane cut-off feature
- Adjustable heat intensity in 1% increments room
temperature to 250 degrees c.
- Reaction is detected automatically
- Manual override of all timer functions
- Alphanumeric readout
- All Functions and parameters entered via key-pad
- Footswitch - RS232 - Printer output (standard)
- Software - USB - Printer (optional)
|