A
high performance data acquisition system, the MP System
data acquisition system with AcqKnowledge™ software
presents a flexible, easy-to-use modular system made to
perform data collection and analyses exactly as you want.
AcqKnowledge™ software is a powerful and flexible
package: Record, analyze and filter data in real time,
then continue analysis after collection. Data can be
plotted in chart-recorder or scope style, as an X-Y
diagram and even as a histogram. You can design complex
data acquisition, stimulation, triggering and analyses
using simple pull-down menus and dialog boxes — no need
to learn a new programming language or protocol. The
hardware is designed to allow easy amplifier additions and
changes so you can customize equipment to match your
research needs. Amplifiers snap together and pull apart
for simple substitutions. Channel number assignments are
made or changed by moving a switch at the top of each
amplifier, and the channel order can be changed in the
software.
The MP System hardware provides a flexible tool for your
research and teaching needs. The modular, powerful
interface system can be used with the add on amplifiers
and accessories or with equipment you already have. The
newly expanded range of amplifiers further enhances your
ability to create a system to suit your application
requirements. Amplifiers snap together and pull apart for
simple substitutions. MP Starter Systems include all
hardware, software and documentation you need to get
started…then you can add amplifier modules, transducers,
and electrodes to match your research design.
Flexible,
friendly data collection
- Intuitive software design lets you get started right away
– no need to learn a new software language
- Full control over channel setup and definition
- Add and save new calculation channels (e.g., heart
rate, integrated data) while collecting raw data
- Real-time digital filtering, bandpass, bandstop, low-
or high-pass filtering
- Save as much data as your computer space or disk
allows–AcqKnowledge has no file size limitations!
Multiple,
changeable display features
- Adjust each wave’s position, amplitude and colour
- Scope mode, histogram function, X-Y mode and Cut
& paste editing
- Live time/event marker; comment markers and typed
comments can be added during or after recording.
Real-time
calculations and Complex analyses
- Rate, integral, derivative and other math functions can be
calculated, displayed and stored in real time
- Use waveform math to transform data while recording
- Measure and display waveform data on the screen (e.g.,
peak-peak, BPM, S)
- Select transformation functions while recording with a
mouse click!
- Fast Fourier Transformation performed easily
- Add, subtract, multiply or divide by a constant or by
another waveform.
- Bring out hidden information with our powerful
transformation functions
- Instantly measure waveform data directly on the
screen, using pop-up menus
- Locate relative minima or maxima or convert peaks to
values quickly with our easy-to-use peak detection
function
|
 |
| |
MP100
System
Includes:
1 MP100ACE High performance data acquisition unit
1 UIM100C Universal interface module
1 ACK100W AcqKnowledge software for Windows with
manual
1 CBLS100 Analog and digital connection cable set (2
cables)
1 CBLSERA MP100 to computer serial connection cable
1 USB1W Windows USB adapter
1 AC100A 12V Power Transformer (specify USA or EURO
power cord).
Amplifier
modules for MP100 systems
A
full range of high performance differential amplifiers
is available for use with the MP100 and MP150 system.
These single-channel amplifiers are optimized for
specific physiological signals. With the systems large
dynamic range, only a few controls are necessary. To
obtain more channels, just snap the modules together up
to 16. All amplifiers employ user-selectable filter,
offset, and gain controls. Interfacing the DA100’s 2mm
pins to other transducers is easily accomplished by
plugging in a TCI Adapter. All of the "C"
modules now are configured for the DIN standard 1.5mm
safety socket.
|
MP150 Systems
include:
1 MP150ACE Ethernet-ready data acquisition unit
1 UIM100C Universal Interface Module
1 ACK100W AcqKnowledge software for Windows with
electronic manual
2 CBLETH1 Ethernet cables
1 ETHSW1 Ethernet switch box
1 AC150A 12V Power Transformer (specify USA or EURO
power cord).
The
MP150 offers Ethernet-ready data acquisition and
analysis. Record multiple channels with differing
sample rates. Record at speeds up to 400 kHz
(aggregate). Place one or more MP150 Systems in a
local area network (LAN). Use any PC in the LAN to
record from any MP150 System in the LAN. Recommended
configuration: MP150 System and local area network
connected to the computer’s Ethernet port via the
Ethernet Switch. This configuration provides optimal
performance when connecting both an MP150 System and a
network to the computer. In cases where the computer
has no Ethernet port, an industry standard PCI
Ethernet card or adapter is required. Minimum computer
requirements: PC: Ethernet Interface with Windows 98,
98SE, 2000, NT4.0, and ME. Recommended minimum RAM: 64
Mbytes. Macintosh: System 8.6 or better, RAM: 64
Mbytes. Power PC native (Power PC 601 or better
required)
|
|
| |
|
|
| |
|
SPECIFICATIONS |
| |
MP150 |
MP100 |
| Analogue
Inputs |
X |
X |
| Number
of Channels |
16 |
16 |
| Input
Voltage Range |
±10V |
±10V |
| A/D
Resolution |
16
Bits |
16
Bits |
| Accuracy
(% of FSR) |
±0.003 |
±0.003 |
| Input
impedance |
1.0
M |
1.0
M |
| Analogue
Outputs |
X
Colour
|
X |
| Number
of Channels |
2 |
2 |
| Output
Voltage Range |
±10V |
±10V |
| D/A
Resolution |
16
bits |
12
bits |
| Accuracy
(% of FSR) |
±0.003 |
±0.02 |
| Output
Drive Current |
±5mA
(max) |
±5mA
(max) |
| Output
Impedance |
100
M |
100
M |
| Digital
I/O |
X |
X |
| Number
of Channels |
16 |
16 |
| Voltage
Levels |
TTL,
CMOS |
TTL,
CMOS |
| Output
Drive Current |
±20mA
(max) |
±20mA
(max) |
| External
Trigger Input |
TTL,
CMOS compatible |
TTL,
CMOS compatible |
| Min
Sample Rate |
2
samples/hour |
2
samples/hour |
| Trigger
Options |
Internal,
External or Signal Level |
Internal,
External or Signal Level |
| Amplifier
Module Isolation |
Provided
by the MP unit |
Provided
by the MP unit |
| CE
Marking |
EC
Low Voltage and EMC Directives |
EC
Low Voltage and EMC Directives |
| Leakage
Current |
<8µA
(Normal), <400µA (Single Fault) |
<8µA
(Normal), <400µA (Single Fault) |
| Fuse |
2A
(fast blow) |
2A
(fast blow) |
| Max
Sample Rates |
X |
X |
| MP
Internal Memory |
200K
samples/sec (400K aggregate) |
70K
samples/sec (70 K aggregate) |
| PC
Memory/Disk |
200K
samples/sec (400K aggregate) |
11K
samples/sec (16K aggregate) |
| Internal
Buffer Size |
6M
samples |
16K
samples |
| Serial
Interface Type/Rate |
Ethernet
DLC type II (10M bits/sec) |
Serial:
RS422 (800K bits/sec) |
| Transmission
Type |
Ethernet
(10/100 Base T) |
USB
(via USB1W or USBIM) |
| Maximum
Cable Length |
100
meters (Ethernet cable) |
7
meters (USB + SERIAL cable) |
| Power
Requirements |
12VDC
@ 2 amp (uses AC150A) |
12VDC
@ 2 amp (uses AC150A) |
| Dimensions |
10cm
x 11cm x 19cm |
7
cm x 29cm x 25cm |
| Weight |
1.0
kg |
1.8
kg |
| Compatibility |
Ethernet
Interface |
USB
Interface |
|
MODELS |
| MP150WS |
Data Acquisition,
Ethernet-ready, for Macintosh |
 |
| MP150WSW |
Data Acquisition,
Ethernet-ready, for Windows |
 |
| MP100WS |
Data Acquisition,
Ethernet-ready, for Macintosh |
 |
| MP100WSW |
Data Acquisition,
Ethernet-ready, for Windows |
 |
| Accessories |
| DA100C |
Gen’l Purpose Wideband
Differential Amplifier Module |
 |
| ECG100C |
Electrocardiogram Amplifier
Module |
 |
| EEG100C |
Electroencephalogram
Amplifier Module |
 |
| EMG100C |
Electromyogram Amplifier
Module |
 |
| EOG100C |
Electrooculogram Amplifier
Module |
 |
| ERS100C |
Evoked Response Amplifier
Module |
 |
| GSR100C |
Galvanic Skin Response
Amplifier Module |
 |
| PPG100C |
Photo-plethysmogram
Amplifier Module |
 |
| RSP100C |
Respiration Pneumogram
Amplifier Module |
 |
| SKT100C |
Skin Temperature Amplifier
Module |
 |
| STM100C |
Stimulator Module |
 |
| STMISOD |
Stimulus Isolation Adapter
for STM100C (0-100 V) |
 |
| STMISOE |
Stimulus Isolation Adapter
for STM100C (0-200 V) |
 |
| STMISOC |
Stimulus Isolation Adapter
(constant current & 0-200 V) |
 |
| TEL100C |
Remote Module Set,
4-channel 10 meter (uses Smart Sensor
connectors) |
 |
| CBL102 |
Cable, BNC to 3.5 mm plug
(6 ft) |
 |
| TCI102 |
Connector for WPI
Transducers |
 |
| Connectors
for other transducers available.“C”
version modules above have Touchproof® 1.5
mm plugs, except DA100C (2 mm pins). |
|
|
 |
| Manual  |
 |
 |
 |
 |
 |
 |
 |
|
 |