The KD Scientific Legato 100 and 200 series offer
unparalleled ease of use through the high resolution
touch screen user interface. The full touch screen
interface enables the user to quickly create
configurations and recall them for ease of use. The TFT
colour display presents all the pump operating
parameters on an easy to view run screen. The password
feature prevents accidental configuration changes
ensuring the program integrity is retained. The pumps
are versatile and can be interconnected through the
RS485 interface. Legato 100 and 200 series models can be
mixed and matched in the daisy chain offering maximum
flexibility. Up to 99 pump can be linked together
through the RS485 interface. The Legato optimizes your
lab bench space. For limited laboratory space the Legato
100 and 200 series can be placed on its side to reduce
the footprint. The display can also be changed to allow
the user to operate the pump vertically.
LEGATO 100 INFUSE ONLY SYRINGE PUMP

Infuse only single syringe pump. Accommodates syringes
from 0.5ul to 60ml. User definable flow rates with
selectable target volume or time values to control the
total infusion volume. Features:
-
Holds one syringe from 0.5ul to 60ml
-
Stall detection
-
High resolution colour touch screen
-
Unparalleled ease of use
-
Password protected touch display
-
Run LED light on front panel
-
Full metal chassis
-
Built in syringe table
-
Up to 30 lbs/13kg linear force
-
Advanced microstepping techniques
-
Built in RS485 interface
-
USB port
-
I/O & TTL interface
-
Continuous mode of operation
-
Spill dam
LEGATO 101 DUAL SYRINGE INFUSE ONLY SYRINGE
PUMP

Infuse only dual syringe pump. Accommodates syringes
0.5ul to 10ml. User definable flow rates with selectable
target volume or time values to control the total
infusion volume. Features:
-
Holds one or two syringes from 0.5ul to
10ml
-
High resolution colour touch screen
-
Unparalleled ease of use
-
Touch pad "lock" feature
-
LED light on front panel
-
Full metal chassis
-
Built in syringe table
-
Up to 30 lbs linear force
-
Advanced microstepping techniques
-
Built in RS485 interface
-
USB port
-
I/O & TTL interface
-
Continuous mode of operation
-
Spill dam
LEGATO 110 SINGLE SYRINGE INFUSE/WITHDRAW
PROGRAMMABLE

Single syringe infuse/ withdraw with program option for
2 programs. 50 steps each. Accommodates syringes 0.5ul
to 60ml. User definable flow rates with selectable
target volume or time values to control the total
infusion volume. Features:
-
Holds one syringe from 0.5ul to 60ml
-
High resolution color touch screen
-
Unparalled ease of use
-
Touch pad "lock" feature
-
LED light on front panel
-
Full metal chassis
-
Built in syringe table
-
Up to 30 lbs linear force
-
Advanced microstepping techniques
-
Built in RS485 interface
-
USB port
-
I/O & TTL interface
-
Continuous mode of operation
-
Spill dam
-
Programmable
LEGATO 111 DUAL SYRINGE INFUSE/WITHDRAW
PROGRAMMABLE

Dual syringe infuse/withdraw with program option for 2
programs. 50 steps each. Accommodates syringes 0.5ul to
10ml. User definable flow rates with selectable target
volume or time values to control the total infusion
volume. Features:
-
Holds one or two syringes from 0.5ul to
10ml
-
High resolution colour touch screen
-
Unparalleled ease of use
-
Touch pad "lock" feature
-
LED light on front panel
-
Full metal chassis
-
Built in syringe table
-
Up to 30 lbs linear force
-
Advanced microstepping techniques
-
Built in RS485 interface
-
USB port
-
I/O & TTL interface
-
Continuous mode of operation
-
Spill dam
|
Specifications - Legato
100/101/110/111 |
|
Accuracy: |
± 0.5% |
|
Reproducibility |
± 0.05% |
|
Syringes (Min/Max) |
0.5 ul to 60ml |
|
Flow Rate: |
Minimum (0.5 ul
syringe): 1.28 pl/min
Maximum (10ml syringe): 25.99 ml/min
Maximum (60ml syringe): 88.28 ml/min |
|
Display |
4.3 WQVGA TFT Color
Display with Touchpad |
|
Non-Volatile Memory |
Stores all Settings
|
|
Connectors: |
RS485 - IEEE-1394 6
pos
USB - Type B
I/O & TTL - 15 pin D-Sub Connector |
Linear Force (Max)
|
13.6 kg (30 lbs) @
100% Force Selection |
|
Drive Motor |
0.9 degree Stepper
Motor |
|
Motor Drive Control |
Microprocessor with
1/16 microstepping |
Number of Microsteps
per one rev. of Lead Screw |
15,360 |
|
Step Rate - Minimum |
27.5 sec/ustep |
|
Step Rate - Maximum |
26 usec/ustep |
|
Pusher Travel Rate - Minimum |
0.15 um/min |
|
Pusher Travel Rate - Maximum |
159 mm/min |
|
Power |
100-240 VAC: 50/60 Hz,
50 W, 0.5 A fuse |
|
Dimensions |
22.6 x 19.05 x 15 cm
(9 x 7.5 x 5 in) |
|
Weight |
2.66 kg (5.9 lbs) |
|
Operating Temperature |
4 degree'C to 40
degree C (40 degree F to 104 degree F) |
|
Storage Temperature |
-10 degreeC to 70
degree C (14 degree F to 158 degree F) |
|
Humidity |
20% to 80% RH non
condensing |
|
Mode of Operation |
Continuous |
|
Classification |
Class 1 |
|
Pollution Degree |
1 |
|
Installation Category |
11 |
|
Regulatory Certification |
CE, UL, CSA, CB
Scheme, EU RoHS |
LEGATO 200 INFUSE ONLY SYRINGE PUMP
Infuse only dual syringe pump. Accommodates 2 syringes.
User definable flow rates with selectable target volume
or time values to control the total infusion volume.
Features:
- Holds one or two syringes from 0.5ul to 140ml
- High resolution colour touch screen
- Real time clock
- Unparallel ease of use
- Touch pad "lock" feature
- LED light on front panel
- Full metal chassis
- Built in syringe table Up to 75 lbs linear force
- Advanced microstepping techniques
- Built in RS485 interface
- USB port I/O & TTL interface
- Continuous mode of operation
- Spill dam
LEGATO 210 INFUSE/WITHDRAW
SYRINGE PUMP
Infuse/withdraw Syringe pump. Holds
2 syringes This unit supports infuse only, withdraw
only, infuse/withdraw, withdraw/infuse and
continuous mode. User definable flow rates with
selectable target volume or time values to control
the total infusion volume.
LEGATO 210P INFUSE/WITHDRAW
PROGRAMMABLE SYRINGE PUMP
Programmable Legato 210P dual
syringe pump with user defined
configurations/programs of up to 800 steps. Up to 40
programs of 20 steps each step can be stored in
memory. Same features as the Legato 210, but
programmable.
LEGATO 270 PUSH/PULL SYRINGE PUMP
Push/pull syringe pump.
Accommodates two syringes for
infusion and two syringes for withdrawal. This model
supports infusion and withdrawal simultaneously at
user defined flow rates and with selectable target
volumes to control the total volume pumped. It also
supports infuse only, withdraw only,
infuse/withdraw/ withdraw/infuse and continuous
mode. user defined flow rates with selectable target
volumes.
-
Holds four syringe from 0.5 ul
to 140ml
-
High resolution colour touch
screen
-
Real time clock
-
Unparallel ease of use
-
Touch pad "lock" feature
-
LED light on front panel
-
Full metal chassis
-
Built in syringe table
-
Up to 75 lbs linear force
-
Advanced microstepping
techniques
-
Built in RS485 interface
-
USB port I/O & TTL interface
-
Continuous mode of operation
-
Spill dam
LEGATO 270P PUSH/PULL SYRINGE
PUMP
Programmable Legato 270P push/pull
pump with user defined program configurations of up
to 800 steps. Up to 40 programs of 20 steps each can
be stored in memory. Same features as the Legato
270, but programmable.
|
Specifications - Legato
200/210/210P/270/270P |
|
Accuracy: |
± 0.35% |
|
Reproducibility |
± 0.05% |
|
Syringes (Min/Max) |
0.5 ul to 140ml |
|
Flow Rate: |
Minimum (0.5 ul
syringe): 5pl/min
Maximum (140ml syringe): 220.97 ml/min |
|
Display |
4.3 WQVGA TFT Color
Display with Touchpad |
|
Non-Volatile Memory |
Stores all Settings
|
|
Connectors: |
RS232 - 9Pin D-Sub
Connector
RS485 - IEEE-1394 6 pos
USB - Type B
I/O & TTL - 15 pin D-Sub Connector |
Linear Force (Max)
|
34 kg (75 lbs) @ 100%
Force Selection |
|
Drive Motor |
1.8 degree Stepper
Motor |
|
Motor Drive Control |
Microprocessor with
1/16 microstepping |
Number of Microsteps
per one rev. of Lead Screw |
6,400 |
|
Step Rate - Minimum |
27.5 sec/ustep |
|
Step Rate - Maximum |
26 usec/ustep |
|
Pusher Travel Rate - Minimum |
0.36 um/min |
|
Pusher Travel Rate - Maximum |
190.80 mm/min |
|
Power |
100-240 VAC: 50/60 Hz,
50 W, 0.5 A fuse |
|
Dimensions |
8.89 x 25.4 x 27.94 cm
(3.5 x 10 x 11 in) |
|
Weight |
4.9 Kg (10.75 lb) |
|
Operating Temperature |
4 degree'C to 40
degree C (40 degree F to 104 degree F) |
|
Storage Temperature |
-10 degreeC to 70
degree C (14 degree F to 158 degree F) |
|
Humidity |
20% to 80% RH non
condensing |
|
Mode of Operation |
Continuous |
|
Classification |
Class 1 |
|
Pollution Degree |
1 |
|
Installation Category |
11 |
|
Regulatory Certification |
CE, UL, CSA, CB
Scheme, EU RoHS |
DESIGNED TO MEET TODAY’S CHALLENGES In
today’s economic environment, multiple users with
different experiments are using the same pump. The next
generation of pump had to meet this demand to store and
recall multiple programs. The pumps role in the
experiment now changes more readily with multiple users
and multiple tests being done using a single pump.
ENGINEERED TO MEET GLOBAL REGULATORY COMPLIANCE
Worldwide use of our pumps and changing regulatory
compliance meant designing the pump to meet RoHS and
WEEE, CE, UL, CSA, and CB schemes. The Legato has lead
free boards and is designed to the latest safety and
EMI/RFI standards. |