Manual or Programmable PC
control with user-friendly GUI interface
- Fast LAFF solenoid valve
- Colour-coded polyurethane tubing for easy identification
- Super low dead volume (<80 nL) micromanifold
- Economically priced
MPS-2 is a programmable
8-channel perfusion system designed for single channel and
whole-cell patch preparations. It offers the best
combination of performance and value. The MPS-2
incorporates the same high quality solenoid valves found
on similar but much more expensive systems. Unlike other
perfusion systems on the market, which often compromise
performance to fit every possible application. The MPS-2
is the only perfusion system designed and optimized
specifically for single-channel and whole-cell patch
perfusion applications. The MPS-2 is therefore the best
perfusion system on the market for these specific
applications and is offered at a very attractive price.
The system can be controlled manually (i.e., via membrane
switches on the front panel) or through a PC. Two
different manual control modes are offered. One controls
each channel independently and the other mode allows the
user to assign a master channel that will keep the system
flow when all other channels are switched off.
User-friendly graphic timing software is included, and the
programmed perfusion sequence can be started by computer,
a patch clamp amplifier or other external trigger, or
manually by the user. The perfusion fluid flows through specially designed
colour-coded
polyurethane ribbon style tubing. The colour-coding allows
the user to easily trace each channel for diagnostic or
set up. The ribbon style of the tubing keeps the system
very neat and clean. Unlike PVC based tubing, polyurethane
tubing contains no plasticizer, which can caused
contamination. The tubing ribbon is designed as an
economical disposable item, which is often critical when
cleanness is needed.
The most unique feature of the MPS-2 is its perfusion
micromanifold. Using the latest microfluidic techniques,
the injection moulded micromanifold provides the least flow
resistance and dead volume of any product on the market.
The flow channel inner diameter is approximately 1.0 mm,
except for the last 5 mm before the junction point. This
design allows a fast flow rate without using a pressured
system. The maximum flow rates are 1 and 16 microliter per
second for the 15 mm long 100 µm and 250 µm ID tips,
respectively. Small channels and a unique design at the
merging point further reduce the chance of cross
contamination. Dead volume is less than 80 nL. The
injection-moulded micromanifold is also designed as an
economical disposable item, eliminating problems of
cross-contamination from other experiments.
|