Multi-channel Blood Pressure Systems
Multi-channel MRBP Blood Pressure Systems for mice and rats. Quick and accurate blood pressure measurements. Test up to 200 animals at a time.
|
![]() |
This revolutionary design brings non-invasive blood pressure testing to a new level — a true turn-key system for accurate, consistent blood pressure measurement on mice, rats or any other laboratory animal test subject.
It is a compact, simple yet versatile system that can test from one to 200 animals at a time with independent control of each channel. Simple daisy-chaining allows expansion of up to 200 independently controlled systems.
All components are built into one small unit — controls, inflation of tail cuff, warming environment with whisper-quiet fans — providing an ideal system for teaching facilities and for the pharmaceutical industry when high throughput is a must.
Single animal systems are controlled from the touch screen, which allows keying in all necessary test setups. Touch screen control allows ease of operation, supplying automatic evaluation of test results — systolic, diastolic, mean and heart rate.
Multi-animal systems can be controlled via software provided. Both single and multi-channel systems can be controlled via the software supplied.
Data is collected, stored, displayed and can be transferred to the supplied memory stick. The USB interface allows for software control of multi-channel systems. For single animal systems, built-in software lets you view and export data. Reports are in an Excel-style format and may be easily exported.
The system is easily cleaned. Removable trays are included with each system.
How it Works
Place an animal in the supplied restrainer, attach tail cuff, set the desired temperature of the warming chamber, select number of test cycles, press auto calibrate and run test. The tail cuffs require the minimum amount of heat to measure blood pressure. The average temperature for rats is 32ºC and for mice 34ºC. The tail cuff design consists of a photoelectric cell, the most accurate method for obtaining tail cuff blood pressure pulses. Other systems heat metal platforms to as high as 40ºC to take measurements, causing undo thermo stress.
Warming Chamber
The warming chamber is an independent environment that you control through the touch screen interface. Heating plates and room temperature are not a factor. Warm air is delivered to the housing by a small fan which generates a calming “white noise” resulting in consistent and accurate readings.
Software
When testing multiple animals, the system is supplied with the proprietary blood pressure software which allows for complete control of all functions and parameters from the software. All data is shown,